Home » DG-6

DG-6

DG-6 - Standard

6 GPH
~7,000 CFM
The DG-6 shares the efficiency of the larger DG-12. It features the same unique, slim design, and air distribution module, but significantly shorter in height, allowing for easier integration to various growing facilities.
  • Electricity consumption of only 6 kW.
  • Plug & play. Easy placement in the center or side of the greenhouse, along the aisles, on the ground or hung.
DG-6DG-6 EU
For EU countries only
DimensionsDepth
930 mm
Depth
3’ -0 3/4”
Depth
933 mm
Width
2,320 mm
Width
7’ -7 1/4”
Width
2,570
Height*2,075 mm
(2,435 mm with air
distribution module)
6'-9 3/4
(7’ - 11 3/4” with air
distribution module)
1,920 mm
(2,435 mm with air distribution module)
Water condensation
@18 °C ,80% RH
24 L/h6 G/h25 L/h
Air flow~12,000 m3/h~ 7,000 CFM~13,500 m3/h
Electricity consumption6 kw6.5 kw
Weight~550 kg~1210 lb~850 kg
Type of Refrigerant R507R507R513a
Electricity requirements60 Hz3 phase, 208V, 60 Hz
I(Oper. max)= 30 Amp
OR3 phase, 460V, 60 Hz
I(Oper. max)= 16 Amp
50 Hz3 phase, 400V, 50 Hz
I(Oper. max)= 18 Amp
3 phase, 400V, 50 Hz
I(Oper. max) = 35 Amp

Air Circulation:

Why does air circulation matter so much?

The DG-6 uses double-sided air input and has a patent protected design that creates uniform and constant climate conditions throughout the entire greenhouse. The powerful air circulation (7,000 CFM or 12,000 m3/h) is a clear advantage for commercial greenhouses with high plant density.

When the greenhouse is isolated, the unit collects the cold and humid air from between the plants, and “throws” it dry and warm in each direction to create unique 360° flow of dry air around the plants’ foliage.

This unit is available with the SmartDG upgrade – Realtime Humidity Control & Data.

Powerful Dehumidification:

Why do you need professional humidity control for greenhouse crops? 

The unit is designed to condense 24* L/h (6 G/h) of water, ~288 L/night (12 hours) (~76 G/night), the highest extraction rate on the market. It utilizes only 12 kW of electricity.

*At designed conditions of 18°C, 80% RH

Covered Area:

When calculating the area that can be covered by a single DG-6 unit it is important to take in consideration plant density, average daily temperature and radiation intensity. We use the “Leaf area index” (LAI) to characterize plant canopies and recommended number of units for the best results:

DryGair DG-6 covered area LAI
1,500 to 2,000 m2 1-2 (For example micro leaves)
Up to 1,000 m2 2-3 (For example Basil)
Up to 750-1,000 m2 3-4 (For example Tomatoes)
Up to 500 m2 4+ (For example Medical Cannabis)
  • Contact us for information about your LAI

Related products and add-ons

Minimize Energy Consumption & get Fast ROI with the “DryGair Solution”:

The DryGair Solution growing concept is based on closing the greenhouse, fully spreading the thermal screen (if applicable), and operating the DryGair unit. The unit heat-exchange technology treats the air, circulating it throughout the crops to create optimal uniform climate conditions for the plants. The unit utilizes the fans to suck the humid air from between the plants from the bottom of the greenhouse.

The DryGair Solution gives the grower the ability to control humidity levels and achieve homogeneous climatic conditions for long period of time while preventing 100% of heat loss from ventilation, and without the fluctuations typical to the traditional dehumidification solution of heating & ventilating.

DryGair dehumidification ROI

 

 

 

DG-6 - Split

6 GPH
~7,000 CFM
We understand the growers’ need to maximize the utilization of greenhouse space using tables and machinery. The DG-6 split upper and lower compartments can be positioned according to the greenhouse’s specific limitations.
  • Identical performance to the DG-6 standard unit.
  • Easy integration in complex growing facilities with one or more levels of crop, moving\non moving tables, no aisles, low roofs etc'
  • The bottom compartment houses the isolated compressor department. The top compartment includes fans, evaporation and condensation coils.
  • Spraying booms can move under the units.
DG-6DG-6 EU
For EU countries only
Upper partLower partUpper partLower part
DimensionsDepth
1,120 mm (3'- 8")
Depth
820 mm (2'-8 1/4")
Depth
933 mm
Depth
820 mm
Width
2,300 mm ( 7' - 6 1/2")
Width
1,655 mm (5'- 5 1/4")
Width
2,570 mm
Width
1,900 mm
Hight*1,160 mm (3'-9 3/4").
+~500 mm (~1'-7 3/4") with
air distribution module
950 mm (3'-1 1/2")1,215 mm.
1,625 with air distribution
module.
940 mm
Weight~330 kg (725 Ib)~325 kg (715 lb)~540 kg~360 kg

In order to accommodate smaller greenhouses, and maximize space use, this unit is available in a split configuration.

The split unit includes two sections:

• Lower section that includes the compressor and the electrical switchboard.
• Upper section in which the air treatment is performed.

Both the upper and lower sections have a pair of copper tubes that should be connected between them, connecting the compressor to the air handling section of the unit. The split unit sections can be placed one next to each other, or one above the other (air treatment section above the compressor and electrical switchboard). In both cases, the upper unit must be at a height of at least 50–60 cm from the floor.

This unit is available with the SmartDG upgrade – Realtime Humidity Control & Data.

For information about the DG-6 split unit installation options please contact us with the form below

Alphabets Only
Alphabets Only
This field is for validation purposes and should be left unchanged.

Contact Us

Whatsapp